Loading... Please wait...

Our Newsletter


Biolight BLT-M9000 Veterinary Patient Monitor

  • Biolight BLT-M9000 Veterinary Patient Monitor
Price:
$1,350.00
Brand:
Condition:
New
Availability:
2
Quantity:
Bookmark and Share


Product Description

BLT M9000Vet Biolight Patient Vet Monitor.  M9000 has FDA approval for monitoring of vital signs functions. Recommended for use in hospital and clinics, for ECG, Respiration-breathing also NIBP-non invasive blood pressure, Pulse rate, SPO2, Temperature, (optional IBP and Multi-gas/O2) parameters.  Features of the monitor are listed below.

Standard Configuration includes : SpO2,NIBP,PR,HR,T and ECG.

  • 12.1" LCD display- high resolution
  • Digital SPO2 technology offers anti-motion and anti-low perfusion functions
  • 168 hours storage
  • Bed to bed view
  • Product Specification/Models
  • Safety: IEC60601 (GB9706)
  • Dimension: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply : 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm
  • 1800 groups of alarm events review
  • Application: Adult, Pediatric and neonate

ECG 

  • Leads: I, II, III, aVR, aVL, aVF, V
  • Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Input impedance: = 5MO (d.c.~60Hz)
  • Common Mode Rejection Ratio: = 85dB (diagnostic mode) = 105dB (monitoring & surgical mode)
  • Bandwith: 0.5-40Hz (monitoring mode) 0.05-120Hz (diagnostic mode) 1-25Hz (surgical mode)
  • Protection: Segregation breakdown voltage 4000VAC, 50/60Hz Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
  • Indication of Detachment of electrodes: Available
  • Playback of Cardiogram: Available
  • Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate Range: 10-300BPM
  • Accuracy: ±1BPM
  • ECG waveform playback: 30 minutes

NIBP 

  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement: Systolic pressure/diastolic pressure/mean pressure
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg,
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, hours
  • 1000 groups of NIBP measuring data review

RESP 

  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
  • BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: ±2% (70%~100%);
  • ±3%(35%~ 69%)
  • Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate: 20~250BPM ±1BPM

TEMP 

  • Channel: 2 channels
  • Range: 0~50°
  • Unit: Celsius, Fahrenheit
  • Resolution: 0.1°
  • Accuracy: ±0.1? (25°~50°)
  • Alarm Range: 0~50°

IBP 

  • Channel: 2 channels
  • Range: -50~300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2 mmHg (±2%) without probe ±4 mmHg (±2%) with probe
  • Unit: mmHg, Kpa
  • Converter sensitivity: 5 uV/V/mmHg
  • Names of pressures: ART/PA/CVP/LAP/RAP/ICP

EtCO2 (side stream) 

  • Method: Infrared spectrum
  • Range: 0.0-13.1%
  • Resolution: 1 mmHg (0.1%)
  • Accuracy: 5% EtCO2

Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!


Add to Wish List

Click the button below to add the Biolight BLT-M9000 Veterinary Patient Monitor to your wish list.

You Recently Viewed...